whatsapp

Why does premature piston seal wear occur?

Premature seal wear can be caused by various factors. Cavitation or air presence in the system requires checking and possible replacement of the suction pipe with a larger diameter one. Excessive pumped water pressure or temperature needs operational parameter control and adjustment. Extended bypass operation must be limited to no more than 5 minutes, while abrasive solids presence requires installing an adequate filter on suction.